Robot Coupe MicroMix Stick Blender
|
Plug the machine into the mains, making sure you do not press the (BC) button
Insert the foot into the preparation.
Press the control button (BC), and the power mixer will start up.
To stop the power mixer, release the control button (BC)
Follow steps 1 to 3 above, then:
Change the speed of the motor by turning the variable speed button (MV) towards the maximum or minimum as required
Chemical - Suma Surface Sanitiser + Suma Multi-Purpose Cleaner
|
Procedure to follow should the stick blender become accidentally immersed during use.
Do not touch the blender, the container, or the worktop.
Unplug the blender from the wall socket.
Lift the blender out of the preparation.
Tilt the blender to allow as much of the liquid to drain out as possible.
Do not switch the blender back on, as there is still a risk of electric shock. Blender will need to be serviced.
The blender must be clean between each job thoroughly.
![]() Fill a jug with hot water and Suma Surface Sanitiser. Pulse blender in sanitiser for 10 seconds. Do not submerge motor. | ![]() Wipe dry. Dismantle the blender as demonstrated in “Assembly and Operations” video. | |
![]() Remove blade from end of blender using the tool provided.
| ![]() Spray and wipe parts with Suma Multi-Purpose Cleaner. |
The blades are subject to wear and tear, and may need to be replaced from time to time to ensure the consistent quality of the end product.
At first, try to identify what has cause the power mixer to stop.
Check the power supply.
Check that the blades are free to rotate and are not too tight.