Combi Oven Cleaning & Operating Guide

Combi Oven Cleaning & Operating Guide

 

 

 

 

 

iCombi Pro 61G

 

 

 

 

 

 

 

Parts Diagram

General Safety

  • DO NOT PLACE ANY OBJECTS ON THE UNIT

  • DO NOT STORE ANY FLAMMABLE OR COMBUSTIBLE SUBSTANCES NEAR THE UNIT

  • AVOID PLACING THE UNIT NEAR HEAT SOURCES E.G GRILL PLATES OR DEEP FRYERS

Safety Instructions Before Use

  • MAKE SURE THE UNIT IS AT A TEMPERATURE OF AT LEAST + 5°C

  • ENSURE THE AIR BAFFLE IN FRONT OF THE FAN WHEEL IS LOCKED AT THE TOP AND BOTTOM

  • MAKE SURE THE HINGING RACK OR THE MOBILE OVEN RACK ARE LOCKED

Safety Instructions After Use

  • CLEAN THE UNIT AFTER EVERY USE

  • TO PREVENT CORROSION IN THE COOKING CABINET, LEAVE THE CABINET DOOR SLIGHTLY OPEN IF IT IS GOING TO BE IDLE FOR A PROLONGED PERIOD AND OVERNIGHT

Personal Protective Equipment

  • When working with the unit, only wear your approved uniform. This will help protect against heat, splashing hot liquids or corrosive substances.

  • Wear protective gloves for reliable protection when handling hot objects and sharp-edged trays.

  • Wear tight-fitting protective glasses and chemical-safe protective gloves when cleaning to ensure reliable protection when handling care products.

Operations

Start-Up Screen

Loading The Unit

  1. Open the cabinet door.
    The brakes on the fan wheel will be activated and this will brake the fan wheel.

  2. Push the food into the unit.

  3. If you are grilling or frying the food, put a container under the food to collect the fat.

  4. Close the cooking cabinet door. Make sure that the cooking cabinet door is fully closed and the cooking cabinet door handle is in the vertical position.

NOTE: In the event that the unit has been without power or switched off for less than 15 minutes, the process will continue from where it was interrupted.

Removing Hinging Rack

  1. Hold the right hinging rack in the middle and press it upwards.

  2. Take the hinging rack off the hinges and remove it from the cooking cabinet.

  3. Lift the left hinging rack and swivel it in the cooking cabinet.

  4. Press the hinging rack upwards and remove it from the cooking cabinet.

 

Operating Instructions

  1. Ensure unit is turned on.

  1. Select cooking process from menu.

  1. Allow unit to preheat. Do not load food prior to alarm sounding to load product.

  1. Load product and close door.
    Cooking cycle will begin with remaining cook time visible.

  1. End of cycle. Remove product.

     

NOTE: Abort cooking process: If a process is selected by mistake you can abort by holding down the return arrow.

Internal Core Temperature Probe

CAUTION: HOT CORE PROBE. Always wear protective gloves when working with the hot core probe. If necessary, cool down the core probe using the hand shower.

How To Use Probe

Product

Procedure

Product

Procedure

Meat

Insert the core probe up to the handle into the food at an angle so that the core probe is as far into the food as possible.

Insert the probe into the thickest point of the food.

For small foods, insert the core probe into as many pieces of food until the core probe is full with food from the tip to the handle.

Whole Chicken

Insert the core temperature probe up to the handle into the thickest point of the breast filler, not too close to the ribs.

Make sure that the tip of the core probe does not protrude into the abdominal cavity of the chicken. Do not insert the core probe into the leg.

Fish Fillets

Insert the core probe up to the handle into the food at an angle, so that the core probe is as far into the food as possible.

 

Whole Fish

Insert the core probe up to the handle into the thickest point of the food,

 

Make sure the tip of the core probe does not protrude into the abdominal cavity of the fish.

Vegetables

Insert the core probe up to the handle into the thickest point of the food.

 

Soups, Sauces, Desserts

  1. Place the core probe in the Gastronorm container so that the core probe is completely covered with liquid.

  2. When stirring the liquid, make sure that the core probe remains in the Gastronorm container.

Baked Goods

  1. For baked goods that rise during baking, place the core probe vertically in the middle of the product.
    To do this, use the optional positioning aid.

Remove Core Probe

  1. Once the food has reached the desired result, first carefully remove the core probe from the food.

  2. Once you have cleaned the core probe, insert it into the holder provided and then remove the food from the cooking cabinet.

Using The Hand Shower

CAUTION: HOT WATER. Wear protective gloves.

NOTE: The hand shower is not to be used to cool down the cooking cabinet. This will damage the unit.

  1. Pull the hand shower at least 20 cm out of the parked position.

  2. Hold the hand shower hose firmly.

  3. Press the lever on the hand shower. The harder you press the lever, the stronger the water stream will be.

  4. After use, let the hand shower slowly retract into the housing.
    Ensure the hose of the hand shower is clean before letting it retract into the housing.

NOTE: If you pull the hand shower out beyond the maximum hose length or rip the hose, the automatic retraction system of the hand shower may be damaged. Then hand shower will no longer automatically retract into the housing.

Cleaning Hand Shower

  1. Rinse the hand shower through with water in the morning and in the evening for 10 seconds.
    This will prevent germs forming in the water line.

Cleaning

Daily Cleaning

Chemical - Combi Care-Tabs

  • Drip pans must be wiped out every day.

  • Combi will suggest a cleaning cycle at the end of the day

  • Only use the “fast clean” option if it is within service times

  1. Select cleaning cycle from menu. If the unit is too hot it will instruct you to cool down by opening the cabinet door prior to loading of any chemical.

  1. Remove all trays & grids from the oven along with any loose food scraps.

  1. Add GREEN TABLET to basket inside oven.

  2. Add BLUE TABLETS to the draw on the front of the oven.

CAUTION: WEAR PPE WHEN HANDELING CHEMICALS.

  1. Close door and cleaning cycle will begin automatically. Do not open door during cleaning cycle.

NOTE: Abort cleaning process: If a cleaning process is selected by mistake you can abort by holding down the return arrow.

Confirm the cycle needs to be aborted. Ensure any tablets in the cabinet have been removed (gloves must be worn). Rinse cabinet with hand shower and follow directions on screen.

Confirm the cycle needs to be aborted. Ensure any tablets in the cabinet have been removed (gloves must be worn). Rinse cabinet with hand shower and follow directions on screen.

Weekly Cleaning

Chemical - Suma Light

  • Clean inside the glass door panels with warm soapy water (Suma Light)

  • Drip panels inside glass door panels with warm soapy water (Suma Light)

  • Wipe over vent on bottom left of unit with warm soapy water (Suma Light)

Maintenance Schedule

  • Comcater to service every 6 months

Related content